Clinical Benefit using VITA 3D Master and Classical Color Scale


JOURNAL OF DENTAL RESEARCH 2019 ; Spec Iss 98 (A)(1948):



https://iadr.abstractarchives.com/abstract/19iags-3179625/clinical-benefit-using-vita-3d-master-and-classical-color-scale


Bibliometrische Indikatoren


Impact Factor = 4,914


Autoren

Hannak W*, Bratner S, Boening K, Klinke T1, Beuer F, Jakstat H


Abstract

Introduction: To evaluate the clinical accuracy of the VITA 3D-Master and classical color scale no match templates were used in an in vitro trial. Material and Methods: 57 preclinical students of dentistry from the dental schools of Berlin, Dresden, Greifswald, Leipzig participated in this study. 39 students were female, 18 male with an average age of 23.2 years. All students passed the Ishihara test to identify, and to exclude color deficient participants. Three groups of ceramic faced crowns were used. The dental technicians had to face the groups with defined colors with additional individualization. Following, two dentists matched the color of the crowns by the help of the VITA Easyshade in several turns. The results defined the CIELAB data of the templates. Moreover, the students matched the color of the samples under defined surroundings: distance and light. The option was to identify a first, and a second match using 3D Master and the classical color scale. Results: For statistical evaluation, a comparison of the areas of the triangles with the points 1, LAB of the templates, 2, LAB of the first choice, and 3, LAB of the second choice, was made. The areas of the 3D master had a mean of 22.267, a median of 14.92, and a standard deviation of 19.69. The areas of classical showed a mean of 25.74, a median of 19.21, and a standard deviation of 20.69. The areas of 3D master were clearly smaller than the areas of the classical. This yielded a better reproducibility for the dentist and the dental technician, and thus also for the patient. The difference was highly significant at p< 0.001. Conclusion: With the limitation of this study we can conclude that the 3D Master color scale offers a better option to match tooth color based on the higher number of templates. The study was supported by VITA Zahnfabrik, Bad-Säckingen, Germany

Veröffentlicht in

JOURNAL OF DENTAL RESEARCH


Jahr 2019
Impact Factor (2019) 4,914
Volume Spec Iss 98 (A)
Issue 1948
Seiten -
Open Access nein
Peer reviewed nein
Artikelart Originalartikel
Artikelstatus erschienen - EPub

Allgemeine Daten zur Fachzeitschrift

Kurzbezeichnung: J DENT RES
ISSN: 0022-0345
eISSN: 1544-0591
Land: USA
Sprache: English
Kategorie(n):
  • DENTISTRY, ORAL SURGERY & MEDICINE


Impact Factor Entwicklung

Jahr Impact Factor
2008 3,142
2009 3,458
2010 3,773
2011 3,486
2012 3,826
2013 4,144
2014 4,139
2015 4,602
2016 4,755
2017 5,38
2018 5,125
2019 4,914
2020 6,116
2021 8,924
2022 7,6

FAQs | Impressum | Datenschutz